Login
|
Register
You are not logged in.
Particle Size Analyzers
Suspended Sediment Sensors
Settling Velocity Sensors
Optical VSF Sensors
Radiative Transfer Models
Storm Runoff Sediment Sensor
Sediment Sensor for HydroPower
Industrial Sensors
LISST Instruments
LISST Accessories
HydroLight
Theoretical Studies
Observational Studies
Instrument Development
Frequently Asked Questions
LISST
|
HydroLight
|
SEARCH OUR FAQ
LISST
HydroLight
All FAQs
GO!
Q:
How do we deal with bio-fouling of optical windows ?
Q:
What type of batteries do the instruments use? Where can I get these batteries? How long can the batteries last ?
Q:
What is the effect of particle shape on the measurement ?
Q:
How do the instruments work?
Q:
Do I need to process my data differently when using an optical path reduction module (PRM)?
Q:
What is in the .LOG file that I can create in real-time mode?
Q:
I have a problem with my data and/or my data processing and would like you to have a look at them - can you do that? What data do I need to send to you?
Q:
What is the acceptance angle of the LISST?
Q:
Are there any instrument-specific files that I need in order to use my LISST-100/-100X?
Q:
What is the upper and lower size range for each of the 32 bins of the LISST instruments?
Q:
What is the InstrumentData.txt file and where can I find it?
Q:
Is there a low velocity threshold for the LISST-SL? Does it need a minimum flow speed in order to sample? What is that?
Q:
Can I program the LISST-SL and deploy it without the connection to the top side control box?
Q:
How do I find a distributor?
Q:
Where can I find information about scientific and/or applied research with the LISST instruments?
Q:
I only need a LISST for a short time period - can I rent one?
Q:
I get an error message similar to this when trying to process my data in MATLAB: ??? Invalid MEX-file 'C:\matlab\lisst\factory_info\nlia.dll': C:\matlab\lisst\factory_info\nlia.dll is not a valid Win32 application. What am I doing wrong?
Q:
Can I get a raw data file (.DAT extension) from a file that I've collected in real-time mode?
Q:
Can the LISSTs be used to measure the size and concentration of oil droplets in water?
Q:
What is a USGS B-reel? What is it being used for?
Q:
Is it possible to process multiple LISST-100X files at once? Can I do batch processing of LISST-100X files?
Q:
Where do I find the Volume Conversion Constant (VCC) for my LISST-100X?
Q:
What kind of liquids are safe to use with my LISST instrument if I want to do laboratory work using the LISST-Portable or the test chambers that are available for the LISST-100/-100X/-25X?
Q:
What is a hologram?
Q:
Why can't the LISST-HOLO be used when the flow speed is larger than 0.4 m/s?
Q:
Why does it take 2 minutes to process one hologram?
Q:
Is it possible to get data in real-time from the LISST-HOLO?
Q:
Why doesn't the LISST instruments cover the submicron size ranges?
Q:
Can the LISST-StreamSide handle freezing temperatures?
Q:
Is there some recommendation for the pump flushing time when using the LISST-StreamSide?
Q:
What is scintillation?
Q:
How many open-close cycles are the batteries in the BioBlock capable of?
Q:
Does the BioBlock reduce the working life of the LISST batteries because it has to work more and send signals to the BioBlock?
Q:
Does the BioBlock come into contact with the LISST windows either through the copper plates or some sort of wiper?
Q:
Does the BioBlock restrict the flow through the LISST compared to none fitted? And does this affect the readings of the LISST?
Q:
Which way should BioBlock be mounted in relation to the flow i.e. facing 'upstream' or 'downstream' the prevailing flow?
Q:
Should the zscat measurement be taken prior to fitting the BioBlock?
Q:
Can I fit a BioBlock on all LISSTs?
Q:
What is BioBlock?
Q:
When I try to program my LISST I get an error message: 'Could not find [Instrumentxxxx] section in LISST.INI'. What should I do?
Q:
I have just recovered my submersible LISST from a long deployment and now it is covered in algae and barnacles. How should I clean it?
Q:
Is Sequoia and the LISST instruments ISO certified?
Q:
I need to ship a LISST back for service from within the US. Is there anything I should be aware of?
Q:
I need to ship a LISST back to you for service from abroad. Is there anything I should be aware of?
Q:
What is the difference between the LISST-100 and the LISST-100X?
Q:
What is the threading on the black cap that goes into the hole of the LISST-Portable lid? Is it a standard NPT threading size?
Q:
I have noticed differences between the battery voltage reported back by the 'DB' command given to our LISST-100X instrument and the battery voltages reported back by the query instrument function within LISST-SOP. Also, if measuring the voltage directly on the battery with a voltmeter I get a 3rd value. Why is that, and which one should I believe and/or use?
Q:
What is the minimum battery voltage that my LISST-100X will work with?
Q:
What is the default IP-address of the LISST-HOLO?
Q:
Can the LISST-100X or LISST-STX safely be unplugged from an external battery pack under water?
Q:
What is the noise in the output from the LISST ring detectors?
Q:
Does Sequoia manufacture mooring frames or tripods that I can buy for my LISST, in order to make it easier for me to deploy it?
Q:
How does the LISST measurement of suspended particles compare with transmissometers and other scattering sensors?
Q:
How does the LISST-ST measure size dependent settling velocity?
Q:
How does the LISST-25 instrument obtain a constant calibration measurement of total suspended volume concentration of particles?
Q:
What is the Sauter Mean Diameter (SMD) measured by the LISST-25?
Q:
What is size distribution?
Q:
Can the submersible LISST instruments do "range gating" similar to an acoustic sensor?
Q:
Does the concentration estimate include particles bigger or smaller than the specified size range (1.25 - 250 micron)?
Q:
What are some of the non-standard (custom) configurations made so far?
Q:
Can I buy instruments outside the standard specifications (larger/smaller particle sizes)?
Q:
What is the maximum concentration that the instruments can work in? Why is the useful working range of the instruments specified in terms of optical transmission?
Q:
Why is the size range limited? Can it be expanded to cover a greater dynamic range?
Q:
Can I buy LISST instruments in the green wavelength?
Q:
What is the range of measured sizes?
Q:
Can the instruments be used in the profiling mode?
Q:
Can I store data on the instrument and transmit data up a wire at the same time?
Q:
In the profiling mode how long a wire can I use for data communications?
Q:
Does daylight affect the measurement? How should I deal with it?
Q:
Can I convert the LISST-100 to a LISST-ST and vice versa?
Q:
What is the maximum depth for a submersible LISST instrument?
Q:
How long can the back-up battery preserve my data?
Q:
Can the LISST instruments measure bubbles?
Q:
What is the minimum measurable concentration of suspended material? What sets the limit?
Q:
Can I extend the operating limits by shortening or lengthening the optical path?
Q:
What happens when particles in a natural suspension are outside the measurement range?
Q:
What is the size resolution of the LISST instruments?
Q:
Can I specify a certain refractive index for my measurements of size distribution with the LISST-100?
Q:
Is there any effect of flow disturbance around the instrument?
Q:
Can the LISST-ST be used as a standard LISST-100 ?
Q:
Why does the LISST-ST report settling velocity in only 8 size classes, not 32 ?
Q:
Can LISST instruments be towed? How fast? Is there an effect of tow speed on the measurement?
Q:
What is the best orientation to use the instrument? In laboratory, field?
Q:
What type of mounting should I use ?
Q:
How can I get more than standard life out of the battery ?
Q:
Can I specify a certain refractive index for my measurements of size distribution with the LISST-25 ?
Q:
Can I use a mix of refractive indices ?
Q:
What is the result if the scatterers are aggregates ?
Q:
What is the effect of particle index of refraction on the measurement ?
Sequoia visit to Colombia and Ecuador!
Sequoia's Yogi Agrawal and Ole Mikkelsen visited C'Particulas, Sequoia's Colombian distributor 28-30 November 2011. See the pictures on our
facebook
page!
Association Of Environmental & Engineering Geologists 54th Annual Meeting
Anchorage, AK, 19-23 September 2011, booth 31
CASQA 2011
Monterey, CA, 26-28 September 2011, booth 41
Website design by
Papugai
, copyright © 2008 Sequoia Scientific, Inc.
Site Map
Sequoia Scientific, Inc.
2700 Richards Road, Suite 107, Bellevue, WA 98005
Phone: (866) 212-2226 Fax: (425) 643-0595
Email Us!