Accessories
LISST-100 Alkaline Battery Pack
|
| The
replacement alkaline battery pack for the LISST-100/ST has 24 alkaline
batteries assembled into a custom battery pack to provide the +15, +18
, and –18 volts required. The battery pack is not rechargeable.
The LISST-100X has a smaller number of batteries assembled int oa custom pack to provide the +9 volts required. The battery pack is not rechargeable. |
|
|
|
| | | | LISST-100 replacement Lithium Backup battery | | The
LISST-100 Backup battery is used to protect the datafile memory in the
event of a main battery power failure or disconnect. The lithium
battery come with the mating connector installed and ready for
assembly. | |  50% reduction
 80% reduction
 90% reduction
| | Optical Path Reduction Module | The
Optical Path Reduction Modules (PRM) are use with the LISST-100 and
LISST-ST to reduce the optical path in the field with out the need for
permanent optical path reductions. The bolt on PRMs are available to
reduce the optical path by 50%, 80%, and 90%.
| | | | | LISST-100/LISST-ST Memory Upgrade | | LISST-100/ST Memory upgrade increase the total number of size distributions from 6000 to 24000. | | | | | LISST-100/LISST-ST External AC Power Supply | | External AC power supply for powering LISST-100/ST. International power compatible. | | 
| | The
Full path mixing chamber is installed on to the optics of a standard
path (5cm) LISST-100. The chamber has a volume of aproximately. 100ml
with built in magnetically coupled mixer and drain. Adjustable speed
controller and power supply provided. The Mixing Chamber allows the
submersible LISST-100 to also be used as a laboratory particle size
analyzer. | |  | | Small Volume Full path Flow Through Chamber | | The
Full Path Flow Though Chamber is installed on to the optics of the
standard path (5cm) LISST-100. The chamber allows sample to be pumped
through the chamber. When combined with a pump and stirred sample
container the Flow Through Chamber allows the submersible LISST-100 to
be used as a laboratory particle size analyzer. | |  | | Adjustable Thin Cell Flow Through Chamber | | The
Thin Cell Chamber has an adjustable optical path from 10mm to 2mm. The
thin cell allows for higher concentrations than the full path
instrument. The mounts in the optical path but it must be submerged in
clean water during operation. The standard Large Volume Test Chamber
can be used to submerge the thin cell. When combined with a pump and
stirred sample container the Thin Cell Chamber allows the submersible
LISST-100 to be used as a laboratory particle size analyzer. | | 
| | Integrated Power and Communications Cables | | Integrated
Power and Communications cables are available for the LISST-100X/ST in
lengths of 20,30 and 50 meters. The yellow jacketed cable has a
breaking strength of 1000 pounds. The standard underwater connectors
for communications and power are molded to the cable. | |  | | Replacement 2-meter Communications Cable | | Two meter communications cable with 4-pin underwater connector and DB-9 Serial Port connector. | | | | | High Performance Conductivity and Temperature Sensor | | High
Precision Conductivity and Temperature can be added to the LISST-100 by
adding a SeaBird SBE-37SI sensor to the LISST-100. The integrated
sensor provides high precision conductivity and temperature for each
size distribution. The values are stored in the standard LISST-100
datafile. High performance depth sensor can also be added to the
SBE-37SI. | |  | | Replacement Large volume test chamber | Replacement
large chamber that is provided standard with the LISST-100 and
LISST-25. Has o-ring seal that allows the optics end of the instrument
to be submerged while the instrument is horizontal on the bench.
Available for both the LISST-100 and LISST-25.
| | 
| | Custom
optical paths are available for both the LISST-100X and LISST-25X. Custom
paths that have been done includes 25mm, 10mm, 5mm, 3mm, and 1mm. | |
|
 |
 |  | | LISST-WING |  | | Sequoia announces the availability of the airborne cloud droplet sensor based on laser diffraction technology. Key features: a large swept volume (90 l/s at 60 knots airspeed), no need for velocity data, and up to 16Hz recording of the size distribution. For more information, contact us. | |  |  |  | | |  |
|